Remote Mount Pressurizer with Pre-cleaner

Specifications

  • Mounting: Vertical or horizontal
  • Filter Options: MERV 16
  • Precleaning Efficiency: > 90% @ 5 u in normal operating range
  • Operating Parameters: Ideal operation range: 0-130 C.F.M (0-3.68119 m³m)
    Extended operation range: up to 250 C.F.M. (7.07921 m³m)
    Operation temperature: -40° C to +85° C continuous; +100° C short exposure
  • Dimensions: With Rain Cap installed, approximately 19.1" x 10.1" x 10.3" (48.51 x 25.65 x 26.16 cm); weighs 9.8 lbs. (4.45 kg) with rain cap
  • Cab Pressurization: Maintains designed cab pressurization over extended operating periods, even when A/C is off, resulting in dramatically increased operator comfort